Back |
|
| |
Welcome to MANAKKODAM LIGHT HOUSE
|
|
|
 |
|
|
 |
Directorate of Lighthouses & Lightships, Cochin20 |
 |
MASTER LEDGER
MANAKKODAM LIGHTHOUSE |
| |
| 1. |
Name |
: |
MANAKKODAM |
| 2. |
Sr.No ( in A.L.O.L ) |
: |
F0705 |
| 3. |
Position |
: |
Lat |
09° 45.0’ N |
| Lon |
76° 17.10’ E |
| 4. |
Elevation |
: |
34m |
| 5. |
Characteristic |
: |
Fl (2) W10Sec |
| |
Tel No. |
|
0478-2562364 |
| 6. |
Range in N miles |
|
|
| |
(i) |
Luminous |
|
15.1 NM |
| |
(ii) |
Geographical |
: |
16.6 NM |
| 7. |
Lighthouse Tower |
|
|
| |
(i) |
Type |
: |
Square RCC tower |
| |
(ii) |
Height |
: |
33.8 m |
| |
(iii) |
Colour Scheme |
: |
White |
| 8. |
Optical Equipment |
|
|
| (a) |
Optic |
|
|
| |
(i) |
Make |
: |
J Stone Co,Kolkata |
| |
(ii) |
Type |
: |
300 mm IV th order revolving |
| |
(iii) |
No of panels |
: |
4 |
| |
(iv) |
Area of Dioptric portion |
|
- |
| |
(v) |
Area of Catadioptric portion |
|
- |
| |
(vi) |
Total Corrected Area |
: |
306 cm2 |
| |
(vii) |
Divergence |
|
|
| |
|
Horizontal |
: |
07o 38’ 24’’ |
| |
|
Vertical |
: |
11o 27’ 14’’ |
| |
(vi) |
Duration of flash |
: |
0.64 Sec |
| (b) |
Pedestal |
: |
Ball bearing type |
| (c) |
Rotation device |
: |
Direct drive system with 20 kg stepper motor |
| (d) |
RPM |
: |
3 RPM |
| (e) |
Illuminant: |
: |
Cluster of 3 Nos150W/230V |
| |
|
Metal Halide Lamps |
| (f) |
Effective Beam Intensity |
: |
14700 Candelas |
| 9. |
Lantern |
|
|
| |
(i) |
Diameter |
: |
2.40 m |
| |
(ii) |
Height of glazing |
: |
1.38 m |
| |
(iii) |
No of panels |
: |
12 |
| |
(iv) |
Ventilators |
: |
8 |
| 10. |
Energy source |
| |
(i) |
Local mains, |
: |
Main supply440 V, 3 phase 50 HZ |
| |
(ii) |
Emergency |
: |
Secondary battery 12 V/150 AH |
| |
(iii) |
Standby |
: |
Diesel Generator set |
| 11. |
Details of UPS |
| Sr No |
Make |
Type |
Capacity |
Input |
Output |
Qty |
| 1 |
Celtron |
Offline |
500VA |
12 V |
230 V |
One |
| 12. |
No of Diesel Generator Set |
: |
1 No |
| |
Details of Diesel engine |
| Sr. No |
Engine No |
Make |
Type |
No. of cylinders |
RPM |
HP |
Cooling |
| A |
02/1002/9231 |
Kirloskar |
HA 294 |
02 |
1500 |
19 |
Air |
| |
Details of Alternator |
| Sr No |
Serial No |
Make |
KVA |
Volts |
Hz |
Phase |
RPM |
| A |
03005 |
KEL |
12.5 |
230 |
50 |
Single |
1500 |
| 13. |
Automatic voltage stabilizer |
| Sr No |
Make |
Capacity |
Input |
Output |
Qty |
| 1 |
AE Electrical Ltd |
7.5KVA |
180-270 V |
230 V± 1% |
1 No |
| 14. |
Batteries |
| Sr No. |
Where used |
Qty |
Type |
Make |
Volts |
Amp-Hr |
| a |
For starting engines |
02 Nos |
Lead acid |
Exide |
12 |
150 |
| b |
Alarm & AMF panel |
01Nos |
Lead acid |
Exide |
12 |
150 |
| c |
For UPS |
03 Nos |
Lead acid |
Exide |
12 |
150 |
| 15. |
Battery Charger |
| Sr No. |
Make |
Cap. In Amps |
Volts |
Qty |
| a |
Transformers & Allied Electricals |
5 Amps |
12 V |
1 No |
| b |
Elak |
12 Amps |
12/24 V |
1 No |
| 16. |
Fire Fitting Equipments |
|
| Sr No |
Equipment |
Type |
Capacity |
Qty |
|
| i |
Fire Extinguisher |
DCP type |
4.2 Kg |
2 Nos |
|
| ii |
Fire Extinguisher |
Form type |
9 ltr |
2 Nos |
|
| iii |
Sand Bucket |
- |
- |
2 Nos |
|
| iv |
Water Buckets |
- |
- |
2 Nos |
|
| |
|
|
| 17. |
Communication |
: |
04782562364
Intercom provided between LH Tower, Power house & HLK Quarters |
|
| |
|
|
|
|
|
18. |
Water Supply |
: |
Panchayat water supply collected in a 2000 ltr capacity water tank buried. A monoblock pump of 2 HP capacity is used to pump water from buried tank to RCC overhead tank. A masonry tank of 5000 ltr capacity to collect rain water to each Qtrs |
|
|
19. |
Land |
|
|
|
(i) |
Area |
: |
0.6686 Hectare |
|
|
|
(ii) |
Demarcation |
: |
Masonry compound wall |
|
|
|
(iii) |
No of fruit bearing trees |
: |
62 |
|
|
|
(iv) |
No of non –fruit bearing trees |
: |
10 |
|
|
|
|
|
|
|
|
|
20. |
Building |
: |
Inspection Quarter, Office cum store room & Power House, HLK Qtr, ALK (S/S) Qtr (2 nos), LHA Qtr, LHS Qtr(twin unit ),Pump house |
|
|
21. |
Compound Wall |
: |
Brick masonry |
|
22. |
Street Light |
: |
10 nos street light fittings and 2 gate light
Fittings |
| 23. |
Staff |
(i) |
HLK |
|
01 |
|
| |
(ii) |
ALK (S/S) |
|
02 |
|
| (iii) |
LHA |
|
01 |
|
| (iv) |
LHS |
|
01 |
|
| 24. |
Mode of approach |
: |
By rail up to Cherthala Railway station, then 14 Km by road up to LH |
|
| |
|
|
|
|
| 25. |
Facilities available |
: |
Dispensary, police station, Post office, Higher Secondary School, etc within 6 km from Lighthouse |
|
| 26. |
Postal address |
: |
Head Light Keeper,
Manakkodam Lighthouse.
P.O. Andhakaranazhy,Via,
Pattanakkad, Cherthala, Dist. Aleppy.
Pin-688531 |
| 27. |
Cost Details |
|
|
|
| (i) |
Construction |
: |
Rs 2,92,000/- |
|
| (ii) |
P.V.Equipment |
: |
Rs 3,30,822/- |
|
| (iii) |
Incandescent to Metal Halide lamp & three point Lamp Changer |
: |
Rs 82,500/- |
|
| 28. |
Date of Commissioning |
|
|
|
| (i) |
Incandescent main lamp and PV as stand by |
: |
01.08.1979 |
|
| (ii) |
Conversion of incandescent lamp to Metal Halide lamp with DC Halogen lamp as stand by |
: |
21.09.1998 |
|
| (iii) |
Conversion of 3 point lamp changer to 3 nos cluster lamp |
: |
22.11.2006 |
|
|
| |
The Manakkodam Lighthouse is about 40 km south of Cochin and 8 Km from Pattankad on NH-47. There is a metalled road up to the Lighthouse. There is a shallow bay in front of the Lighthouse. It is the main source of fishing. A net work of brackish water canals and ponds for Prawn culture has been developed in the region. The region was part of Trvancore state prior to independence. Travancore state was merged with Kerala state on 1st November 1956.
There wasn’t any system of aids to navigation in this regio
n earlier to this Lighthouse main purpose of which is to assist the coastal shipping. A 30m cylindrical tower was first planned in 1972 which had to be changed to a four column RCC structure supporting a service room in order to reduce the load on the foundation wells due to the weak substrata. The completion of the project was considerably delayed. The tower could be completed in 1979 and the equipment supplied by M/s. J. Stone, India, was installed on it. The lighthouse was commissioned on the 1st August 1979. Subsequently the incandescent light source was replaced by a 230 V 400W Metal halide lamp on 21stSeptember 1998. The direct drive system was also integrated simultaneously.
|
|
|
|
|
|